The automation is ready for the set‑up cycle.
Press the button (OK)
The control unit buzzer emits 4 beeps and the set‑up cycle starts.
The door starts, closing until approach is achieved, then it performs an opening cycle at slow speed,
which it must necessarily complete.
At the end of the opening, a prolonged BEEP signals that set-up is over.
After a short time the door automatically closes.
Select the selector of the door work program.
OFF = Digital selector ET-DSEL or T-NFC.
ON = Mechanical selector EV‑MSEL.
Contact setting on the STOP/INTERLOCK input between the terminals 14-19 of the control unit
ET‑LOGIC‑B.
Select ON with a normally open contact or if you do not connect any device on the input.
Select OFF if you use a device with a normally closed contact.
Contact configuration on OPEN input between terminals 18-19 of the ET-LOGIC-B board.
Select ON with a normally open contact or if you do not use the OPEN input.
Select OFF if you use a device with a normally closed contact.
Only if the functions S09 and/or S10 are set to ON.
Select test logic status, used by the automation control unit to monitor safety sensors.
The setup depends on the characteristics of the sensor installed.
Most safety sensors available on the market operate with test low logic level (OFF = factory setting).
For details, refer to the paragraph “Safety sensors”.
Only if S07 and/or S08 functions are set to ON
Select ON if the monitored opening safety sensors have been installed (as required by standard EN
16005) to activate sensor test at the beginning of each cycle; select OFF only if the opening safety
sensors have not been set up to be monitored.
For details, refer to the paragraph “Safety sensors”.
Only if S05 and/or S06 functions are set to ON
Select ON if the monitored closure safety sensors have been installed (as required by the standard EN
16005) to activate the sensor test at the beginning of each cycle; select OFF only if the closing safety
sensors have not been set up to be monitored.
For details, refer to the paragraph “Safety sensors”.
Select ON only if an opening safety sensor has been installed on input E.O.2.
Select ON only if an opening safety sensor has been installed on input E.O.1.
Select ON only if a closure safety sensor has been installed on input E.C.2