56
25) MAINTENANCE
To enter, type the 10-character technical password (for more information, refer to the “Password management” paragraph).
This section is accessed only to reset any fault existing in the events memory and the partial counter of the door opening/closing cycles
performed by the door and to reset the initial setup carried out during commissioning.
The event memory and partial counter reset must be performed by specialized personnel only during routine maintenance, after
performing all system operation checks.
The buttons in this section are used as follows:
•
The button ν
allows moving forward in the reset type selection.
•
The button ^
F2
allows returning to the previous reset.
•
The button
F1
(OK) allows confirming data reset for the selected reset type.
•
The button
F3
is only used if the digital selector ET-DSEL is connected to two automations for the management of two automatic
doors and the symbol in the top right section of the display indicates 1 if the reset operations refer to automation 1, or 2 if they refer
to automation 2.
Each time you press the button
F3
, you switch from 1 to 2 and vice versa.
If the selector ET-DSEL only manages a single automation, the symbol "1" is displayed on the top right.
GENERAL RESET
resets the set-up and returns the electronic control unit to factory settings.
25.1) PLUG AND PLAY
The Plug and Play option allows to set the functions and the parameters of the automatic door directly at the workshop, before shipping
the automation to the installation site.
To adjust the functions and parameters, refer to the paragraph "Functions and Adjustments".
After you have selected the desired functions, enter the "MAINTENANCE" section of the digital selector ET-DSEL described in this
paragraph, select with the arrow the option "PLUG and PLAY" and press and hold the button F1 (OK).
The buzzer of the electronic control unit emits 5 beeps.
Cut off the power supply to the automation.
Once you have finished the installation of the automatic door, follow the next steps to perform the initial set-up of the automation:
a)
MOVE THE DOOR TO CLOSED POSITION TO ALLOW THE AUTOMATION TO AUTOMATICALLY DETECT THE CORRECT
DIRECTION OF TRAVEL DURING SET-UP.
b) Power the electronic control unit with 230V grid voltage, It will emit 5 short beeps.
c)
Press and hold the button PS1 (START) on the electronic control unit until the start of the initial set‑up cycle, or alternatively, enter
the section "INITIAL SET-UP" of the general programming menu and select the option "PARTIAL" from set-up type.
d) During the set-up cycle, the door moves slowly from closed position to fully open position to establish leaf run.
At the end of the opening a long BEEP signals that set-up is over.
e) Now the door will operate in accordance with the preset functions.