Simons Voss Technologies GatewayNode 2 Скачать руководство пользователя страница 1

GatewayNode 2

Manual

17.06.2021

Содержание GatewayNode 2

Страница 1: ...GatewayNode 2 Manual 17 06 2021...

Страница 2: ...a 12 8 Initial operation 15 8 1 IPsettings 15 9 Maintenance 16 10 Signalling 17 11 Fault rectification 18 11 1 Reset 18 12 Technical specifications 20 12 1 Optional external antenna 22 12 1 1 Electric...

Страница 3: ...1 General GatewayNode 2 Manual 1 General 3 27...

Страница 4: ...y the product only when needed and only in the manner described in the documentation IMPORTANT Damage resulting from electrostatic discharge ESD This product contains electronic components that may be...

Страница 5: ...t or place the product directly next to devices that could cause electromagnetic or magnetic interference switching power supplies Communication interference due to metallic surfaces This product comm...

Страница 6: ...afting in the contract language are translations of the original instructions Read and follow all installation installation and commissioning instructions Pass these instruc tions and any maintenance...

Страница 7: ...isconnect the network cable before opening the housing NOTE Unauthorised access with standard access data The standard access data can be viewed freely Unauthorised persons can not change the access a...

Страница 8: ...Tab Example Name of a displayed window Example Upper programme bar Example Entry in the expanded upper pro gramme bar Example Context menu entry Example Name of a drop down menu Example Selection opt...

Страница 9: ...y available accessories to adapt your device to different applications Order code Name Purpose ANTENNA EXT 868 External antennas You can connect the external antenna to the MCX connector of the circui...

Страница 10: ...he connectors of the IO connector at RouterNode 2 Connection Meaning DC In Pin connector Power supply with round plug connector IO Vout Terminal block GND Auxiliary voltage output Earth connection Ter...

Страница 11: ...s If the electrical contacts in the device are short circuited by unauthorised persons undesired re actions may occur Mount the device in an environment that is protected from unauthorised access Malf...

Страница 12: ...oint 1 Do not remove any bars that have a clip over them 2 Do not damage clips during sawing 4 Use a suitable saw to saw through the bars at both ends of the desired opening to the base plate 5 Bend t...

Страница 13: ...protected area while the antenna is outdoors The scope of delivery of the external antenna includes Integrated magnetic base Wall mounting material Dowels and screws You do not need to change any set...

Страница 14: ...the circuit board 3 Connect the external antenna to the connector socket 9 The external antenna is connected 4 Close the housing again 9 The device transmits via internal and external antenna GatewayN...

Страница 15: ...ignment of an IP address by a DHCP server in the network Unless you make other settings an IP address is automatically assigned to your device by a DHCP server You can change this IP address manually...

Страница 16: ...ormance of your radio network at regular intervals CAUTION Network failure in critical situations With the System 3060 and WaveNet you can implement emergency func tions such as amok protection These...

Страница 17: ...Meaning Green flashing 1 5 Hz Configured and ready to use Green flashing 0 3 Hz Not configured but ready for opera tion Red flashing briefly Restart Green flickering Data transfer GatewayNode 2 Manual...

Страница 18: ...uration Reset all network settings IP address DHCP settings host name NOTE IP address recovery If the IP address is assigned by a DHCP server default setting the DHCP server assigns the IP address aga...

Страница 19: ...authorisations but they can change the network configuration You will then no longer be able to reach the device via the network and will have to reset it Some browsers do not transmit spaces at the b...

Страница 20: ...applications MCX socket optional external antenna Power supply via PoE and round plug possible simultaneously round plug 12 VDC Round plug used round plug 12 VDC PoE used Environment Temperature Oper...

Страница 21: ...P 1x for Digi Scan OAM tool Web server Enable 868 MHz radio WaveNet interface range up to 30 m Analogue input 1x with 12 bit resolution from 0 to 3 3 VDC Relay contacts 1x change over contact potentia...

Страница 22: ...ype Multiband antenna Frequencies AMPS 824 894MHz GSM 900MHz DCS 1800MHz PCS 1900MHz 3G UMTS 2 1GHz Impedance 50 Polarization Linear Gain 2 2dBi max VSWR 3 1 Operating temperature 40 C to 85 C 12 1 2...

Страница 23: ...m 12 1 3 Mechanical specifications and dimensions Mounting Magnetic Mount Material ABS Max dimensions 30 9mm x 71 5mm x H Weight 50g weight with connection above Colour Black GatewayNode 2 Manual 12 T...

Страница 24: ...14 30 EU EMC as well as the corresponding UK statutory 2016 No 1091 EMC 2012 19 EU WEEE as well as the corresponding UK statutory 2013 3113 WEEE 2011 65 EU RoHS as well as the corresponding UK statuto...

Страница 25: ...imons voss com en certificates html Information on disposal Do not dispose the device MK SMARTBRIDGE ER WNM RN2 ER IO WN RN2 ER SI GN2 ER M in the household waste Dispose of it at a collection point f...

Страница 26: ...Address SimonsVoss Technologies GmbH Feringastr 4 D 85774 Unterfoehring Germany GatewayNode 2 Manual 14 Help and other information 26 27...

Страница 27: ...inable thinking and action and heartfelt appreciation of employees and partners With its headquar ters in Unterf hring near Munich and its production site in Osterfeld eastern Germany the company empl...