COMPONENT MAINTENANCE MANUAL
AVIATION PRODUCTS
Model FA5000
Rev. 02 Page 303
Disassembly
23–70–30
Use or disclosure of information on this sheet is subject to
the restrictions on the cover page of this document.
July 21/17
F
If the RIPS will not fully charge, the unit must be replaced.
F
If the RIPS charges completely, proceed to step 4.
(4) Remove the power from the recorder.
(5) Remove the RIPS from the recorder.
(6) Store the RIPS according to Section 3.
NOTE:
No additional regular maintenance is required.
3. STORAGE INSTRUCTIONS
A. Storage of the RIPS Module in Original Container
When possible, store the RIPS in its original container. Provide adequate packing to
ensure protection from damage during storage and shipment and ensure that ade-
quate silica gel packages are packed in the containers to protect the equipment from
moisture. Seal the container to provide a moisture–proof package and place in a
cool, dry location. Refer to Section B. if the RIPS has been stored for one year or
more.
B. Storage of RIPS Without Original Container
If the original container is not available, perform the following procedures to wrap the
RIPS for storage. Refer to Section B. if the RIPS has been stored for one year or
more.
1.
Wrap the RIPS in plain wrapping paper or newspaper of sufficient thickness to
thoroughly cover all sharp corners and protrusions.
2.
Enclose the unit in a polyethylene bag (3 mils thick, min.) and seal the bag.
3.
Place the RIPS in a suitably
−
sized heavy construction cardboard box surround-
ed with packing material sufficient to protect it on all sides. Arrange packing ma-
terial in such a way that the unit is protected and will not move around within the
box.
4.
Seal the box with fiberglass packing tape.
5.
Mark the box clearly as to the contents.
6.
Store in a cool, dry location.
The document reference is online, please check the correspondence between the online documentation and the printed version.