COMPONENT MAINTENANCE MANUAL
AVIATION PRODUCTS
Model FA5000
Assembly
23–70–30
Use or disclosure of information on this sheet is subject to
the restrictions on the cover page of this document.
Rev. 02 Page 710
July 21/17
(3) Leave the RIPS charging on the recorder until the “Int RIPS Battery Charge”
displays on the FA5000 CVR Status Web Page reads 100%.
F
If the RIPS will not fully charge, the unit must be replaced.
F
If the RIPS charges completely, proceed to step 4.
(4) Remove the power from the recorder.
(5) Remove the RIPS from the recorder.
(6) Store the RIPS according to Section 3.
NOTE:
No additional regular maintenance is required.
5. STORAGE INSTRUCTIONS
A. Storage in Original Container
When possible, store equipment in its original container. Provide adequate packing
to avoid damage during storage and shipment, and add adequate silica gel pack-
ages to the container to provide a moisture–proof package, and place in a cool, dry
location.
NOTE:
If the RIPS has been stored for one year, refer to Section E.
B. Storage Without Original Container
If the original container is not available, perform the following procedures to wrap the
equipment for storage.
(1) Wrap the equipment in plain wrapping paper or newspaper of sufficient thick-
ness to thoroughly cover all sharp corners and protrusions.
(2) Enclose the unit in a polyethylene bag (3 mils thick, min.) and seal the bag.
(3) Place equipment in a suitably-sized heavy construction cardboard box sur-
rounded with packing material sufficient to protect it on all sides. Arrange pack-
ing material so the unit is protected and will not around in the box.
(4) Seal box(es) with fiberglass packing tape.
(5) Mark the box clearly as to the contents.
NOTE:
If the RIPS has been stored for one year, refer to “Condition
RIPS Module After Expired Shelf Life (One Year in Storage)”.
The document reference is online, please check the correspondence between the online documentation and the printed version.