36
2.5
Connections for 2 SHC - Boxes
When the sprayer is equipped with more then 18 output functions,
there are not enough slots on the PCB. On existing machines this
can happen after adding extra functions like sections, boarder
nozzles, independent slope correction or independent folding. In
that case, we split up the water/section and hydraulic functions
and equip the sprayer with a second SHC box via an extra
Splitterbox.
1x Hydraulics SHC box
1x Water/sections SHC box
1x SHC Splitterbox
FMC
Control box
CAN Cable
Power cable
Splitter
box
Extra
SHC Box
SHC Box
Extra
Splitter
box
Hydraulic
Connectors
Connection
cable to water
valves and
hydraulic valves