16
2.2.3
ISO Connection cable: between Splitterbox & SHC-box
ISO connection cable
Colour
Contact on SHC
PCB
Red (6mm²)
+PWR
Red (2,5mm²)
+pwr
Green
CAN+
Yellow
CAN-
Black (6mm²)
-PWR
Black (2,5 mm²)
-pwr
Black 2.5 mm²
Red 6 mm²
Black 6 mm
2
Red 2.5 mm
2
Yellow 1mm²
Green 1 mm²
Black 2.5 mm²
Red 6 mm²
Black 6 mm
2
Red 2.5 mm
2
Yellow 1mm²
Green 1 mm²
The ISO cable provides power and communication to the Section & Hydraulics PCB at the rear of the machine. The thick red & black wires
(6mm
2
) provide the electrical power for the hydraulic valves and section motors. The thin red & black wires (2,5mm
2
) provide power to the
PCB itself. The green & yellow wires are data communications wires, guiding the information signals between control box and SHC-box.
(see picture SHC input connections)
Содержание TS-T
Страница 5: ...1 2 EC connections 5 For more information please also check the inside of the PCB housing ...
Страница 13: ...13 2 2 Standard Splitterbox connections ...
Страница 17: ...17 2 3 SHC Box input connections ...
Страница 35: ...35 2 4 8 Total overview SHC hydraulic section ...
Страница 38: ...38 2 5 2 2 SHC boxes hydraulics 2 5 3 2 SHC Boxes water sections ...
Страница 45: ...45 2 7 1 ASV system overview Fuse inside Fuse inside ...
Страница 46: ...46 2 7 2 ASV inside Important Please check the jumper positions Mounted Jumper placed Trailed Jumper removed ...
Страница 55: ...55 3 3 Cable and sensor test 3 3 1 Speed sensor machine and flow sensor test Metal ...
Страница 56: ...56 3 3 Cable and sensor test 3 3 Locking sensor test ...