24
2.3.4
Locking sensor
The locking sensor shows the driver that the boom is locked and
ready for folding. When the boom is locked you can see this on
your FMC control box by the red LED. When the red locking light
is on, it automatically blocks the slope correction to prevent
damage.
Locking sensor
Colour
Contact
Brown
+
White
signal
Check the locking sensor signal
The locking sensor only reacts on a magnetic field. It is very
important that you check the signal with a magnet and not with a
metal plate.
Step 1.
Go to your control box test screen and check the LED.
Step 2.
Check if the sensor is reacting on a magnet
Step 3.
Check with the test possibilities the PCB and the locking sensor
AUTO
M
a
g
n
e
t
AUTO
When there is no
magnet in front the
LED should burn
When there is a
magnet in front the
LED should go out
Содержание TS-T