64
Default:
No reg
0.8%
P zone
3%
T on
50 ms
T off
100 ms
Explanation screen:
• No reg = dead zone
• P zone = Area of P zone 1
• T on = time that the
regulator is active in P
zone 1
• T off = time that regular is
not active in P zone 2
Default:
Rev D
0s
P zone
6%
T on
50 ms
T off
100 ms
Explanation screen:
• Rev D= 3% extra active
regulator time when the
valve change direction
• P zone= Area of P zone 2
• T on = time that the regular
is active in P zone 2
• T off time that regular is not
active in P zone 2
Default:
2 sec.
Default:
Sp 50% (speed)
Fl 20% (flow)
PR20% (pressure sensor)
Al2 sec alarm delay time
Explanation screen:
• The time that the regulator
is not reacting after using
main valve
• Q low= Below this number
the software don’t look to
the flowmeter input, but
starts to calculate the flow
Explanation screen:
Filter values for the sensors
20% means 20 % new value
80% old value So lower value
in % more slower the signal.
4.2
FMC-R screen information including parameters
46
47
Содержание TS-T
Страница 5: ...1 2 EC connections 5 For more information please also check the inside of the PCB housing ...
Страница 13: ...13 2 2 Standard Splitterbox connections ...
Страница 17: ...17 2 3 SHC Box input connections ...
Страница 35: ...35 2 4 8 Total overview SHC hydraulic section ...
Страница 38: ...38 2 5 2 2 SHC boxes hydraulics 2 5 3 2 SHC Boxes water sections ...
Страница 45: ...45 2 7 1 ASV system overview Fuse inside Fuse inside ...
Страница 46: ...46 2 7 2 ASV inside Important Please check the jumper positions Mounted Jumper placed Trailed Jumper removed ...
Страница 55: ...55 3 3 Cable and sensor test 3 3 1 Speed sensor machine and flow sensor test Metal ...
Страница 56: ...56 3 3 Cable and sensor test 3 3 Locking sensor test ...