Pos: 22.179 /BA/Info-Center/CCI-ISOBUS-Terminal/CCI-BiG Pack/Hauptmenüs/Hauptmenü 4 Service/Diagnose analoge Aktoren HS Baureihe @ 64\mod_1300169028051_78.docx @ 580255 @ @ 1
Diagnostics analogue actuators
4-4
PWM:
300
I=
0mA
CC000047
Fig.74
A current (in mA) can be created with the PWM value (in parts per thousand).
With a value of PWM = 500, the current should be between 500 mA and 3000 mA (depending
on the valve that is used and the operating temperature).
•
Pressing the function key
increases the PWM.
•
Pressing the function key
decreases the PWM.
Possible analogue actuators
No. Symbol
Description
Y11
Pressure limitation valve
Y17
Start-up aid
State:
actuator ON
actuator OFF
No power supply; fuse is probably defective
Pos: 22.180 /BA/Info-Center/CCI-ISOBUS-Terminal/CCI-BiG Pack/Hauptmenüs/ESC drücken um Menü Service 4 zu schließen bzw. zum Grundbild zugelangen @ 44\mod_1275893530687_78.docx @ 393687 @ @ 1
•
Pressing the function key
closes the called up menu
The display shows menu level 4 "Service".
•
Pressing the function key
and holding it down brings up the basic screen
Pos: 22.181 /BA/---------------Seitenumbruch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1