Kramer Electronics Ltd.
PA-240Z - Protocol 3000
38
AUD-HI-Z
Functions
Permission
Transparency
Set:
AUD-HI-Z
End User
Public
Get
AUD-HI-Z?
End User
Public
Description
Syntax
Set:
Set High Z state
#
AUD-HI-Z
CRChannelSPHiZState,HiZVoltCR
Get:
Get High Z status
#
AUD-HI-Z?
CR
Response
~nn@
AUD-HI-Z
SPChannel,HiZState,HiZVoltCR LF
Parameters
Channel
–
1
(Speaker Output),
2
(Line Level Output)
HiZState
–
1
(Hi-Z state high),
0
(Hi-Z state low)
HiZVolt
– Hi-Z volt level:
0
(70 Volt),
1
(100 Volt),
0xff
(Ignore). Optional, active only in high state
Notes
Active only when state is high. Ignore everything else.
K-Config Example
Set the line level output to Hi-Z and 70V:
“#AUD-HI-Z 2,1,0”,0x0D
AUD-IN-CONF
Functions
Permission
Transparency
Set:
AUD-IN-CONF
End User
Public
Get
AUD-IN-CONF?
End User
Public
Description
Syntax
Set:
Set threshold and time to indicate
when signal is presents or not
#
AUD-IN-CONF
SPChannel,ThresholdDbLevel,TrigTimeDelayCR
Get:
Get threshold and time
#
AUD-IN-CONF?
SPChannelCR
Response
~nn@
AUD-IN-CONF
SPChannel,ThresholdDbLevel,TrigTimeDelayCR LF
Parameters
Channel
–
1
(Speaker Output),
2
(Line Level Output)
ThresholdDbLevel
– input level indicating when a signal is not present, range
-100
to
0
dB
TrigTimeDelay
–
10
(fixed)
K-Config Example
Set the speaker output threshold level and time:
“#AUD-IN-CONF 1,-50,10”,0x0D