![Kramer PA-120Z Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/kramer/pa-120z/pa-120z_user-manual_2000521035.webp)
Kramer Electronics Ltd.
PA-240Z - Protocol 3000
33
FACTORY
Functions
Permission
Transparency
Set:
FACTORY
End User
Public
Get:
-
-
-
Description
Syntax
Set:
Reset device to factory default configuration
#
FACTORY
CR
Get:
-
-
Response
~nn@
FACTORY
SPOKCR LF
Notes
This command deletes all user data from the device. The deletion can take some time.
Your device may require powering off and powering on for the changes to take effect.
K-Config Example
“#FACTORY”,0x0D
HELP
Functions
Permission
Transparency
Set:
-
-
-
Get:
HELP
End User
Public
Description
Syntax
Set:
-
-
Get:
Get command list or help for specific
command
1.
#HELPCR
2.
#HELPSP
COMMAND_NAME
CR
Response
1. Multi-line:
~nn@Device available protocol 3000 commands:CR LFcommand,SP
command...
CR LF
2. Multi-line:
~nn@HELPSPcommand:CR LFdescriptionCR LFUSAGE:usageCR LF
Parameters
COMMAND_NAME
– name of a specific command
Notes
To get help for a specific command use:
HELPSPCOMMAND_NAMECR LF
K-Config Example
“#HELP”,0x0D
MODEL
Functions
Permission
Transparency
Set:
-
-
-
Get:
MODEL
?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get device model
#
MODEL?
CR
Response
~nn@
MODEL
SPmodel_nameCR LF
Parameters
model_name
– String of up to 16 printable ASCII chars
Notes
This command identifies equipment connected to Step-in master products and notifies of identity changes to
the connected equipment. The Matrix saves this data in memory to answer REMOTE-INFO requests
K-Config Example
“#MODEL?”,0x0D