![Kramer PA-120Z Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/kramer/pa-120z/pa-120z_user-manual_2000521036.webp)
Kramer Electronics Ltd.
PA-240Z - Protocol 3000
34
PROT-VER
Functions
Permission
Transparency
Set:
-
-
-
Get:
PROT-VER?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get device protocol version
#
PROT-VER?
CR
Response
~nn@
PROT-VER
SP3000:versionCR LF
Parameters
version
- XX.XX where X is a decimal digit
K-Config Example
“#PROT-VER?”,0x0D
RESET
Functions
Permission
Transparency
Set:
RESET
Administrator
Public
Get:
-
-
-
Description
Syntax
Set:
Reset device
#
RESET
CR
Get:
-
-
Response
~nn@
RESET
SP
OK
CR LF
Notes
To avoid locking the port due to a USB bug in Windows, disconnect USB connections immediately after
running this command. If the port was locked, disconnect and reconnect the cable to reopen the port.
K-Config Example
“#RESET”,0x0D
SN
Functions
Permission
Transparency
Set:
-
-
-
Get:
SN?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get device serial number
#
SN?
CR
Response
~nn@
SN
SPserial_numberCR LF
Parameters
serial_number
– 14 decimal digits, factory assigned
K-Config Example
“#SN?”,0x0D