Kramer Electronics Ltd.
PA-240Z - Protocol 3000
41
AUD-STANDBY
Functions
Permission
Transparency
Set:
AUD-STANDBY
End User
Public
Get
AUD-STANDBY?
End User
Public
Description
Syntax
Set:
Set standby mode
#
AUD-STANDBY
SPStandbyMode,TimeDelayCR
Get:
Get standby mode state
#
AUD-STANDBY?
CR
Response
~nn@
AUD-STANDBY
SPStandbyMode,TimeDelayCR LF
Parameters
StandbyMode
–
0
(Off),
1
(Delayed, auto mode),
2
(Standby mode)
TimeDelay
– 5, 10, or 15 (time delay [min] to standby mode)
Notes
Active only in auto mode
K-Config Example
Set the standby delay time to 10 minutes:
“#AUD-STANDBY 1,10”,0x0D
BALANCE
Functions
Permission
Transparency
Set:
BALANCE
End User
Public
Get:
BALANCE?
End User
Public
Description
Syntax
Set:
Set balance level
#
BALANCE
SPchannel,balancelevelCR
Get:
Get balance level
#
BALANCE?
SPchannelCR
Response
~nn@
BALANCE
SPchannel,balance_levelCR LF
Parameters
channel
–
1
(Speaker output),
2
(Line level output)
balancelevel
–
-15
to
+15
(audio parameter in Kramer units, minus sign precedes negative values)
++
(increase current value)
--
(decrease current value)
K-Config Example
Set the speaker output balance to +12:
“#BALANCE 1,12”,0x0D