Kramer Electronics Ltd.
PA-240Z - Protocol 3000
43
EQ-Q
Functions
Permission
Transparency
Set:
EQ-Q
End User
Public
Get
EQ-Q?
End User
Public
Description
Syntax
Set:
Set Q level
#
EQ-Q
SPChannel,EqType,Q_levelCR
Get:
Get Q level
#
EQ-Q?
SPChannel,EqTypeCR
Response
~nn@
EQ-Q
SPChannel,EqType,Q_levelCR LF
Parameters
Channel
–
1
(Speaker output),
2
(Line level output)
EqType
–
0
(Bass),
1
(Middle),
2
(Treble)
Q_level
–
0
to
15
(Q level)
K-Config Example
Set the line level output treble Q level to 8:
“#EQ-Q 2,8”,0x0D
MUTE
Functions
Permission
Transparency
Set:
MUTE
End User
Public
Get:
MUTE?
End User
Public
Description
Syntax
Set:
Set audio mute
#
MUTE
SPchannel,mute_modeCR
Get:
Get audio mute
#
MUTE?
SPchannelCR
Response
~nn@
MUTE
SPchannel,mute_modeCR LF
Parameters
channel
–
1
(Speaker output),
2
(Line level output)
mute_mode
–
0
(Off),
1
(On)
K-Config Example
Set speaker output to mute:
“#MUTE 1,1”,0x0D