442700/A
389
I/O Setup
page allow you to control the properties of each of the available
communication ports. For each port, you can set up the communication
parameters, and monitor the data flow.
Motion Reference Unit
The motion reference unit (MRU) measures the roll and pitch movements of the
vessel. Some sensor models also measure heave. The information provided by
the motion sensor is used by the CS90 system to stabilize the beams.
Installation Parameters
The
Installation Parameters
pages allow you to define the relationship between
the physical locations of the various sensors and the transducer. All relevant
system units and sensors must be defined with their physical offset values in
relation to the defined
Ship Origin
in the vessel’s coordinate system. You will
only need to define these installation parameters once.
Synchronization
The purpose of the
Synchronization
parameters is to set up the CS90
system to operate alone, or as a master or slave in a synchronized system.
Synchronization is required in order to avoid interference if the CS90 system
is used simultaneously with other hydroacoustic instruments within the same
frequency range.
Units
The user interface presents many measurements. These measurements are for
example related to depth, range and distance. From the
Units
page you control
which units of measurements that are used.
Operating Panel
The Operating Panel offers all necessary control functions for normal operation.
It further allows you to assign certain functions to dedicated buttons and
switches. The
Operating Panel
page is used to select which physical hardware
panel you use, and to assign functionality to the programmable buttons.
Echogram Settings
The CS90 system offers an
inspection
beam. The inspection beam is presented
using an
Inspection
view. Use the
Echogram Settings
page to set up basic
functionality for the
Inspection
view.
Hull Unit Configuration
The hull unit is used to lower the transducer down below the ship’s hull when the
CS90 system shall be used. When the CS90 system is turned off, the transducer
is hoisted for protection. Use
Hull Unit Configuration
to specify the type of
hull unit your CS90 system is using.
Содержание Simrad CS90
Страница 1: ...kongsberg com simrad Simrad CS90 REFERENCE MANUAL ...
Страница 2: ......
Страница 316: ...314 442700 A Related topics User interface page 303 Top bar page 306 Simrad CS90 Reference Manual ...
Страница 410: ...408 442700 A Related topics Menu system page 372 Display menu page 381 Simrad CS90 Reference Manual ...
Страница 627: ...442700 A 625 Related topics Concept descriptions page 622 Concept descriptions ...
Страница 683: ......
Страница 684: ... 2021 Kongsberg Maritime ISBN 978 82 8066 213 2 ...
Страница 685: ......
Страница 686: ...Reference Manual Simrad CS90 ...