OPERATION
EXPLANATION OF COMPONENTS
HYDRAULIC OIL TEMPERATURE GAUGE
Gauge (3) indicates the hydraulic oil temperature.
If the temperature is normal during operation, green range (B) will
light.
If red range (C) lights up during operation, move the fuel control dial
down to approximately 3/4 of High idle (MAX), reduce the load, and
run until the oil temperature enters green range (B). If the oil
temperatures does not enter green range (B) even when the load
is reduced, stop the work equipment control lever and run until the
oil temperature enters green range (B).
(A)
(B)
(C)
White range
Green range
Red range
FUEL LEVEL GAUGE
Gauge (4) fuel level in the fuel tank.
During normal operation, the green range (B) should be lit.
If red range (A) lights up during operation, add fuel immediately. If
this is not done, the engine speed will become irrgular or an error
display will be shown on the monitor.
(A)
(B)
Red range
Green range
REMARK
The display is not proportional to the amount of fuel remaining.
If only the red range (A) lights up, there is less than 270 liters (71.34 US gal) of fuel remaining.
ENGINE PRE-HEATING PILOT LAMP
Lamp (5) indicates that engine is being pre-heated by the electrical
heater during cold weather.
The engine controller detects the coolant temperature and
automatically actuates pre-heating in low temperatures when
starting the engine.
3 - 15
Содержание D475A-5E0
Страница 2: ... 1 1 ...
Страница 14: ... 2 1 ...
Страница 53: ... ...
Страница 54: ... 3 1 ...
Страница 243: ... ...
Страница 244: ... 4 1 ...
Страница 256: ... MAINTENANCE RECOMMENDED FUEL COOLANT AND LUBRICANT ASTM American Society of Testing and Material 4 13 ...
Страница 301: ... MAINTENANCE SERVICE PROCEDURE MAINTENANCE SERVICE PROCEDURE A Right of machine 4 58 ...
Страница 338: ... 5 1 ...
Страница 340: ... 6 1 ...
Страница 401: ... ...
Страница 405: ... D475A 5E0 BULLDOZER Form No PEN00537 05 2016 KOMATSU All Rights Reserved Printed in Japan 12 16 ...