OPERATION
OPERATION
CHECK ELECTRIC WIRING
WARNING
If fuses are frequently blown or if there is a short circuit in the electrical wiring, locate the cause and repair or ask your Komatsu
distributor to check.
Accumulation of flammable material (dead leaves, twigs, grass, etc.) around the battery may cause fire, so always check and
remove such material.
Keep the top surface of the battery clean and check the breather hole in the battery cap. If it is clogged with dirt or dust, wash
the battery cap to clear the breather hole.
Check for damage and wrong capacity of the fuse and any sign of disconnection or short circuit in the electric wiring.
Check also for loose terminals and tighten any loose parts.
Check the wiring of the "battery", "starting motor" and "alternator" carefully in particular.
Always check if there is any accumulation of flammable material around the battery, and remove such flammable
material.
Contact your Komatsu distributor for investigation and correction of the cause.
CHECK THAT LAMPS LIGHT UP
1. Turn starting switch (1) to ON position (B).
2. Turn the front lamp and working lamp switch to ON position
and check that the front lamps and working lamp light up.
3. Turn the rear lamp switch to ON position and check that the
rear lamps on the left and right fenders light up.
If the lamps do not light, check for a broken bulb or
disconnected wire, ask your Komatsu distributor for repairs.
3 - 97
Содержание D475A-5E0
Страница 2: ... 1 1 ...
Страница 14: ... 2 1 ...
Страница 53: ... ...
Страница 54: ... 3 1 ...
Страница 243: ... ...
Страница 244: ... 4 1 ...
Страница 256: ... MAINTENANCE RECOMMENDED FUEL COOLANT AND LUBRICANT ASTM American Society of Testing and Material 4 13 ...
Страница 301: ... MAINTENANCE SERVICE PROCEDURE MAINTENANCE SERVICE PROCEDURE A Right of machine 4 58 ...
Страница 338: ... 5 1 ...
Страница 340: ... 6 1 ...
Страница 401: ... ...
Страница 405: ... D475A 5E0 BULLDOZER Form No PEN00537 05 2016 KOMATSU All Rights Reserved Printed in Japan 12 16 ...