Self-diagnostic Function
It is possible to perform troubleshooting of various sensors and equipment used on the air conditioner.
1. Press OFF switch (1). The temperature setting and air flow display on the liquid crystal display portion go out
and operation stops.
2. If the "
∨
" and "
∧
" parts of temperature setting switch (3) are kept pressed at the same time for at least 3 seconds,
the troubleshooting mode is displayed on the liquid crystal display portion.
<Monitor display and failure mode>
Display
Failure mode
E--
No failure
E11
Disconnection in recirculated air sensor
E12
Short circuit in recirculated air sensor
E13
Disconnection in fresh air sensor
E14
Short circuit in fresh air sensor
E15
Disconnection in coolant temperature
sensor
E16
Short circuit in coolant temperature sensor
E18
Short circuit in sunlight sensor
E21
Disconnection in vent sensor
E22
Short circuit in vent sensor
E43
Problem in vent damper
E44
Problem in air mix damper
E45
Problem in RECIRC/FRESH air damper
E51
Problem in refrigerant pressure
When more than one failure is detected, press the "
∨
" or "
∧
" portion of temperature setting switch (3) to display
the failures in turn.
After completing the troubleshooting, press OFF switch (1) again to return to the normal display.
If any problem is detected by the self-diagnostic function, contact your Komatsu distributor perform inspection and
repair.
3 - 80
Содержание D475A-5E0
Страница 2: ... 1 1 ...
Страница 14: ... 2 1 ...
Страница 53: ... ...
Страница 54: ... 3 1 ...
Страница 243: ... ...
Страница 244: ... 4 1 ...
Страница 256: ... MAINTENANCE RECOMMENDED FUEL COOLANT AND LUBRICANT ASTM American Society of Testing and Material 4 13 ...
Страница 301: ... MAINTENANCE SERVICE PROCEDURE MAINTENANCE SERVICE PROCEDURE A Right of machine 4 58 ...
Страница 338: ... 5 1 ...
Страница 340: ... 6 1 ...
Страница 401: ... ...
Страница 405: ... D475A 5E0 BULLDOZER Form No PEN00537 05 2016 KOMATSU All Rights Reserved Printed in Japan 12 16 ...