Vers. 291020
11
MENU TORQUE & ANGLE:
TORQUE CONTROL
1-
TORQUE CONTROL flag: it allows to select the mode of Torque Control and Angle
monitoring. In this mode, priority is given to the torque. The angle can be monitored by the
lever pressed (or by remote), by a certain set torque threshold, or by an external input (see
point 9). In this mode the TARGET Angle and MAX Torque functions are deactivated.
When this function is active, flag #13 is blank and Angle Monitoring function is on.
2-
Program number.
3-
MAX Torque: (not set in Torque Control mode).
4-
MIN Torque: to set the min torque value. Min Torque and Target functions define the
acceptable torque range for each single application. When the reached torque is within this
range, “Screw OK” will be displayed on the status bar and the green led will light up. If the
reached torque is below this value, the error signal “under minimum torque” will be
displayed and the red led will light up. You can set the torque range from 0 to Target.
5-
Saving key: to save parameters and/or return to the previous menu. If you have changed any
parameters, after touching this key, the SAVE CHANGES screen appears and you have to
choose to save or not. After the, you will return to the PROGRAMS menu.
2
3
4
1
14
10
11
9
15
6
7
8
5
13
12
Содержание 035001
Страница 50: ...Vers 291020 50 EXPLODED VIEW KDU 1 KDU 1A...
Страница 52: ...Vers 291020 52 EXPLODED VIEW KDS PLxx...
Страница 54: ...Vers 291020 54 EXPLODED VIEW KDS PLxxP...
Страница 56: ...Vers 291020 56 EXPLODED VIEW KDS PLxxCA...
Страница 58: ...Vers 291020 58 EXPLODED VIEW KDS MT1 5...
Страница 60: ...Vers 291020 60 EXPLODED VIEW KDS MT1 5P...