Vers. 291020
15
11-
AUTO-REVERSE AFTER TORQUE: This option will automatically start a reverse after a
torque reached signal. You can set time from 0.1 to 10.0 sec and angle from 0 to 30000°.
ATTENTION: During the reverse, it is necessary to keep the lever or the start signal
pressed as long as it doesn’t stop. “Correct screw” will be displayed on the status bar and a
green led will light up. You will hear one beep sound, too. In case the lever is released
before the end of the reverse, “unfinished screw” will be displayed and a red led will light
up. You will hear two beep sounds, too.
12-
Flags of PRE-TIGHTENING REVERSE function. This function can be activated in Time
or Angle mode. Depending on the mode selected, in the small box below, the value of the
active function will be displayed on a white background.
If OFF, the box below will show off in a non-editable gray background.
13-
To set AUTO-REVERSE AFTER TORQUE and AUTO-REV DELAY values.
14-
AUTO-REV DELAY: to set a delay before the Auto-Reverse starts, if AUTO-REV is on
(see # 11). Time can be set from 0.3 to 10 secs.