Vers. 291020
34
Input Program Settings (if REMOTE PR function enabled).
The selection of the programs takes place in binary on PR input as shown in the table:
PR
BIT6PR
PIN11
BIT5PR
PIN10
BIT4PR
PIN9
BIT3PR
PIN8
BIT2PR
PIN7
BIT1PR
PIN 6
PR
BIT6PR
PIN11
BIT5PR
PIN10
BIT4PR
PIN9
BIT3PR
PIN8
BIT2PR
PIN7
BIT1PR
PIN 6
-
0
0
0
0
0
0
32
1
0
0
0
0
0
1
0
0
0
0
0
1
33
1
0
0
0
0
1
2
0
0
0
0
1
0
34
1
0
0
0
1
0
3
0
0
0
0
1
1
35
1
0
0
0
1
1
4
0
0
0
1
0
0
36
1
0
0
1
0
0
5
0
0
0
1
0
1
37
1
0
0
1
0
1
6
0
0
0
1
1
0
38
1
0
0
1
1
0
7
0
0
0
1
1
1
39
1
0
0
1
1
1
8
0
0
1
0
0
0
40
1
0
1
0
0
0
9
0
0
1
0
0
1
41
1
0
1
0
0
1
10
0
0
1
0
1
0
42
1
0
1
0
1
0
11
0
0
1
0
1
1
43
1
0
1
0
1
1
12
0
0
1
1
0
0
44
1
0
1
1
0
0
13
0
0
1
1
0
1
45
1
0
1
1
0
1
14
0
0
1
1
1
0
46
1
0
1
1
1
0
15
0
0
1
1
1
1
47
1
0
1
1
1
1
16
0
1
0
0
0
0
48
1
1
0
0
0
0
17
0
1
0
0
0
1
49
1
1
0
0
0
1
18
0
1
0
0
1
0
50
1
1
0
0
1
0
19
0
1
0
0
1
1
51
1
1
0
0
1
1
20
0
1
0
1
0
0
52
1
1
0
1
0
0
21
0
1
0
1
0
1
53
1
1
0
1
0
1
22
0
1
0
1
1
0
54
1
1
0
1
1
0
23
0
1
0
1
1
1
55
1
1
0
1
1
1
24
0
1
1
0
0
0
56
1
1
1
0
0
0
25
0
1
1
0
0
1
57
1
1
1
0
0
1
26
0
1
1
0
1
0
58
1
1
1
0
1
0
27
0
1
1
0
1
1
59
1
1
1
0
1
1
28
0
1
1
1
0
0
60
1
1
1
1
0
0
29
0
1
1
1
0
1
61
1
1
1
1
0
1
30
0
1
1
1
1
0
62
1
1
1
1
1
0
31
0
1
1
1
1
1
63
1
1
1
1
1
1
64
Not selectable
NB: For security reasons, Kolver has chosen not to associate any sequence if no input is activated.
In this way the possibility of setting the program 64 from remote input is lost. It will however be
possible to set up program 64 manually, with Kolver accessories or communication ports.
OUTPUT:
When activated all CN3 connector outputs (Pins from 23 to 43) provide a 24V DC signal on the
respective pins. The signals can be used to activate LEDs / sensors or read directly from an external
PLC. In this case the negative of the KDU unit (pins 22 and 44) must be shared with the PLC
negative. The total power of the output signals is Max 400mA; if exceeded, a protection circuit
deactivates the output signals and activates an alarm on the display (see figure below). The alarm
signal remains active until the problem remains. Every 2 sec the entire port will be checked to see
if the problem on the outputs has been fixed.
Содержание 035001
Страница 50: ...Vers 291020 50 EXPLODED VIEW KDU 1 KDU 1A...
Страница 52: ...Vers 291020 52 EXPLODED VIEW KDS PLxx...
Страница 54: ...Vers 291020 54 EXPLODED VIEW KDS PLxxP...
Страница 56: ...Vers 291020 56 EXPLODED VIEW KDS PLxxCA...
Страница 58: ...Vers 291020 58 EXPLODED VIEW KDS MT1 5...
Страница 60: ...Vers 291020 60 EXPLODED VIEW KDS MT1 5P...