Vers. 291020
13
MENU RAMP &TIME:
1-
Program number.
2-
ON/OFF flags to enable Ramp, Run Time, Min and Max Time functions. If OFF values in
grey backgrounds are the default values. If ON, values can be set digiting the desired
numbers.
3-
Values of Ramp, Run Time, Min and Max Time functions.
4-
Saving key: to save parameters and/or return to the previous menu. If you have changed any
parameters, after touching this key, the SAVE CHANGES screen appears and you have to
choose to save or not. After the, you will return to the PROGRAMS menu.
5-
Time – Angle – Off: flags referring to PREVAILING TORQUE function. This function can
be activated in Time or Angle mode. Depending on the mode selected, in the small box
below, the value of the active function will be displayed on a white background.
If OFF, the box below will show off in a non-editable gray background.
6-
PREVALING TORQUE: time period or angle the screwdriver works at maximum torque
before switching to the user-set torque. The time is selectable from 0.1 to 19.9 sec and angle
from 1 to 360°. To disable the function, select the OFF flag. This function overlaps with the
other settings starting from the motor start on.
ATTENTION: This function is useful for applications where the prevailing torque is higher
than the final torque (for example self-tapping screws or locknuts). Please use this function
with utmost attention because an incorrect use can damage both the assembly and the
screwdriver. Torque values reached during the max torque time won’t activate the torque
signal and “Error pvt time” will be displayed.
7-
MAX TIME: to select the maximum time of screwing.
IMPORTANT: If torque isn’t reached by the maximum time, the screwdriver will stop.
“Over maximum time” will be displayed on the status bar and the red led will light up. You
will hear two beep sounds, too.
8-
MIN TIME: to select the minimum time of screwing from 0.1 sec to 'Max time - 0.2s' or
'Run Time -0.2s' .
IMPORTANT: Torque reached below the minimum time won’t activate the torque signal
and will result in an error signal. “Below minimum time” will be displayed on the status bar
and the red led will light up. You will hear two beep sounds, too.
9
6
2
3
1
4
5
10
8
7
Содержание 035001
Страница 50: ...Vers 291020 50 EXPLODED VIEW KDU 1 KDU 1A...
Страница 52: ...Vers 291020 52 EXPLODED VIEW KDS PLxx...
Страница 54: ...Vers 291020 54 EXPLODED VIEW KDS PLxxP...
Страница 56: ...Vers 291020 56 EXPLODED VIEW KDS PLxxCA...
Страница 58: ...Vers 291020 58 EXPLODED VIEW KDS MT1 5...
Страница 60: ...Vers 291020 60 EXPLODED VIEW KDS MT1 5P...