Connector Pinout And Descriptions
4/13/2012
Kollmorgen
29
S200 Position Node Installation Guide
J1 Mating Connector Information
Screw Terminal Connector:
12 – 24 AWG Wire Range, Phoenix MSTB2,5/9-STF-5,08-BK
OR
Spring Cage Clamp Connector
12 – 24 AWG Wire Range, Phoenix FKC 2,5/9-SFT-5,08-BK
OR
Crimp Connector
14-20 AWG Wire Range, Phoenix MSTBC 2,5/9-STZF-5,08-BK
Crimp Contact: 14-16 AWG Wire Range, Phoenix MSTBC-MT 1,5-2,5
Crimp Contact: 18-20 AWG Wire Range, Phoenix MSTBC-MT 0,5-1,0
Refer to
www.phoenixcon.com
.
For maximum line droop tolerance connect logic power to 230Vac
instead of 115Vac
WARNING
After powering down the drive, monitor the BUS voltage by
connecting a meter from J1-4 (+BUS) to J1-3 (-BUS) to verify the
internal BUS capacitors have discharged prior to working on the
drive.
WARNING
The Regen input is not short circuit protected. The Regen
Resistance MUST be within specified ranges to prevent damage to
the drive. For example, between 25 to 50
Ω
for the S20260, S20360
drives or 15 to 50
Ω
for the S20660.
CAUTION
To avoid damage to the connector and drive, NEVER plug or unplug J1
with power applied.
WARNING
For single-phase systems Main Bus power must be wired to L1
and L2. Do not connect L3.
WARNING
Selected Regen Resistor must be able to handle constant 390Vdc
connection without risk of fire or must otherwise be thermally
protected with an overload device.
N O TE