Specifications 4/13/2012 Kollmorgen
11
S200 Position Node Installation Guide
Velocity Loop Performance
Maximum Stable Bandwidth (Hz with SFD)
400
Update Period (µs)
0.8
Range (rpm)
0 to 18,300
< 0.001 rpm analog
Command Resolution
0.558 rpm serial
Velocity Loop Compensation
KVP Range (Depends on Ipeak)
0.00044 to 0.106 (Ipeak)(1/rad/sec)
KVP Resolution (%)
10
KVI Range (Hz)
0 to > 22
KVI Resolution (%)
10
ARF0
1
Range (Hz)
24.3 to > 46627
ARF1
1
Range (Hz)
24.3 to > 46627
1
Values for ARF0, ARF1; from 3012 to 24873 Hz cannot be set.
Current Loop Specifications
- 3 dB Bandwidth (Hz)
> 2000
- 45° Phase Lag (Hz)
> 1000
Current Loop Bandwidth
Maximum Bandwidth
AC Input Drive (kHz)
3
DC Input Drive (kHz)
5
Recommended Bandwidth
AC Input Drive (kHz)
2
DC Input Drive (kHz)
3
SFD Auto Set (kHz) AC &
DC
2
Bandwidth Variation For
Fixed Motor L
(% regulated independent of
bus volt)
± 2.5
Update Period (µs)
0.8
Recommended Max Motor Electrical Frequency (Hz)
AC Input Drive (Hz)
600
DC Input Drive (Hz)
900