41
Items
Methods
Temperature
Methods 1: After entering temperature, pressure value, the atmospheric
correction will be calculated automatically and PPM in 4 is displayed.
Method 2: Directly entering the atmospheric correction factor (ppm), after
entry, the values for [Temp], [Press] are erased.
Pressure
Atmospheric correction PPM
Prism constant
Enter the prism constant correction value suited to the reflector used.
Measurement mode
Select it with
or
in following modes:
Fine“r”, Fine AVG“n=”, Fine“s”, Tracking
NOTE
:
Temperature entry range: -40°
~
+60°(step length 1
‵
) or –40
~
+140
℉(
step length 1
℉)
Pressure entry range: 560
~
1066hPa (step length 1hPa) or 420
~
799.5mmHg (step length
1mmHg) or 16.5
~
31.4inchHg (step length 0.1inchHg)
Atmospheric correction PPM entry range: -999
~
+999 PPM (step length 1 PPM)
Prism constant PC entry range: -99mm
~
+99mm (step length 1mm)
Reflector type
:
KTS440R series Total Station can be set infrared laser distance measurement and unvisible
infrared distance measurement
,
The reflector includes prism,non-prism and reflector sheet. You can set by
yourself according to your need.KTS440 series Total Station has the infrared distance measurement function only,
and the prism should match with the prism constant.
9.2 Laser direction and laser plummet
1. Press SFT and press +/- key to enter below screen.
Laser point
F1 Laser point ON
F2 Laser point OFF
Laser Plummet
Intensity: 2
F1 turn on Laser direction
F2 turn off Laser direction
2. Laser Plummet will automatically turn on after entering the interface.
Press▲ or ▼: to adjust the brightness of laser plummet.
Brightness value 0 : the centering device shut down.
Brightness value 4 : the maximum value.
Laser plummet will turn off automatically after quite laser direction inferface.
Note: This fuction is only available on the instruments which equipped with Laser-plummet.