156
⑶
Press REC. to record measured data with“*”,
the screen shows as right diagram.
Input following data: point name, code, target
height.
Press ENT after input all data.
REC.
*N 100.364 ↑
*E 234.897
*Z 49.098
Pt.
:
SS20004
CODE
:
↓
SAVE R.HT CODE
⑷
When the self checking is finished, Press SAVE
to record data. System will creates a new point
number by adding “1” on the base of last point
number. user can use this number directly or create
another number by himself
In order to avoid duplicate record , the function key
REC will not show up until a new measurement
happens.
SAVE
Dist+ Corrd
*N
*E
*Z
Pt.
:
SS20004
OBS. OFFS AUTO
⑸
Press OBS to measure the coordinates again in
Record Mode.
OBS
Coordinate
Coord. PC = 0
PPM = 0
Fine-S
Stop
⑺
Press ESC to return to record mode screen.
ESC
1. Stn data JOB01 ↑
2. Back sight data
3. Angle data
4. Dist data
5. Coord data
6. Dist+ coord data ↓
·
measure coordinate and record distance and coordinate data automatically: AUTO
By using AUTO key, it allows you to measure coordinate and record the result under record mode. The point
number will be original number plus 1, codes remain the same.After recording the result will be displayed for 2
seconds and it returns to the previous screen before pressing AUTO.
·
Offset measurement under Rec. mode
:
OFFS
(Refer to“12. offset measurement”)
21.7 Recording Notes
·
This procedure prepares note data and records it in the JOB which is selected.
PROCEDURE
Operating Procedure
Operation
Display
⑴
Press REC in the second page of MEAS
Mode. The “Record Mode Screen” is displayed.
Enter Page 2.
REC
7. note
8. view