66
PROCEDURE
Operating Procedure
Operation
Display
⑴
Sight the offset point then press SD in the
MEAS Mode Screen.
SD
Dist
Dist PC = 0
PPM = 0
Fine “S”
STOP
⑵
When the measurement is completed, or
during repeat measurement, press STOP, the
slope distance from station point to offset point,
vertical angle, horizontal angle are displayed.
Meas
.
PC -30
PPM 0
S 18.678 m
ZA 89°59′54″
HAR 90°01′00″
P1
SD SHV HSET EDM
⑶
In Meas Mode, display the screen in which
OFFS is registered. Press OFFS to enter the
“Offset Menu Screen” is displayed.
OFFS
Offset
1. Offset/Dist
2. Offset/Angle
3. Offset/2D
4. Stn data
⑷
Select “1. Offset/Dist” then press ENT, the
Offset Observation Screen is displayed.
Select the following items:
1. Horizontal distance from the target point to the
offset point.
2. Direction of the offset point.
After each entry press ENT.
“1.
Offset/Dist”
+
ENT
S 10.865 m
ZA 87°58′38″ 3
HAR 112°34′23″
Dist
:
2.450 m
Direc
:
→
OK OBS
⑸
Press OK to display the Offset Measurement
result screen. There will be different contents
under different measurement mode.
OK
+
COORD
(or DIST)
Offset/Dist
S 10.865 m
ZA 87°58′38″
HAR 112°34′23″
REC COORD
Offset/Dist
N 2.345
E 1.234
Z 0.569
REC DIST
Содержание KTS440 L Series
Страница 9: ...9 3 NOMENCLATURE ...