59
⑷
Select “2. S-O data”, then press ENT, input
following data: 1. prism height 2. the setting-out
point height (the distance from the surveying
point to the point to be set out )
After each entry press ENT.
Select “2.
S-O data”
+
ENT
S-O
Np
:
1223.455
Ep
:
2445.670 3
Zp
:
1209.747
Tgt. h
:
1.620 m
REC READ OK
S-O (2)
SO dist
:
23.450 m
SO H set
:
45°12′08″
OK
⑸
Press OK.
OK
SO
.
H 1.828 M
H 1.828 M
ZA 89°45′23″
HAR 150°16′54″
dHA -0°00′06″
REC SHV <--> HD
⑹
Press SHV, REM is displayed on the
bottom line of the screen.
SHV
SO.Ht m
3
S 80.123 m
ZA 89°45′23″
HAR 150°16′54″
dHA 0°00′00″
REC SHV <--> REM
⑺
Press REM to begin the setting-out, after
0.7 seconds, the distance between the
setting-out data and the measured distance is
displayed on the third line. (S-O. Ht).
Measurement results are displayed every 0.5
seconds.
REM
SO. Ht. –0.002 m 3
S 80.123 m
ZA 89°45′23″
HAR 150°16′54″
dHA -0°00′06″
STOP
⑻
After pressing <-->, then press REM, the
displayed value is the distance from the sighted
point and the setting-out point. Two arrows
mean the required direction meaning of the
arrows:
↑
:
Move the telescope near the zenith.
↓
:
Move the telescope near the nadir.
<-->
+
REM
←
1°00′00″
↑ -0.002
H 80.123 m
ZA 89°45′23″
HAR 150°16′54″
REC SHV <--> REM