86
Note
:
It is also possible to perform area measurement by pressing AREA key under MEAS mode when AREA
function is allocated in soft key. For the method, refer to “20. Key function allocation”.
17. Setting-out line
Setting-out line is used for setting out a required point at a designated distance from the base line and for finding
the distance from the baseline to a measured point.
17.1 Defining Baseline
You need to define the base line before setting out straight line. You can define a baseline by inputting two points‟
coordinates. The scale factor value is the difference between the input coordinate and the observed coordinate.
·
When not observing first or second points, scale factor is set to “1”.
·
Defined baseline can be used in both setting-out line measurement and point projection.
Procedure
Key
Screen display
(
1
)
Under the measurement mode, define the
function of LINE into the soft Key
See 20“key
function
allocation”
Meas. PC -30
PPM 0
S 4.583m
ZA 92 36‟ 25”
HAR 30 25‟ 18”
PROJ LINE HSET EDM