64
Operating Procedure
Operation
Display
⑴
Select “5.EDM” from the Set-Out menu.
Select
“5.EDM”
Set-Out
1. Observation
2. Set-Out data 3
3. Stn data
4. Set H angle
5. EDM
⑵
Select following parameters:
1. Temperature
2. Air pressure
3. Atmospheric correction value PPM
4. Prism constant correction
5. Distance measurement mode
Temp : 20
℃
Press : 1013.0 hPa
PPM : 0
PC : -30
Mode: Fine “s”
0PPM
⑶
Set all parameters and press ENT.
ENT
Set-Out
1. Observation
2. Set-Out data 3
3. Stn data
4. Set H angle
5. EDM
·
Methods and contents
Items
Setting methods
Temperature
Method
①
: After entering temperature and pressure, the atmospheric
correction value will be calculated and displayed in PPM.
Method
②
: Enter the atmospheric correction value PPM, now temperature
and pressure value will be cleared.
Pressure
Atmospheric correction PPM
Prism constant
Enter the prism correction value for current prism
Distance mode
Press
or
to select from following modes:
Fine repetition, Fine N-time, Fine single, tracking
Note:
Temperature input range: -30°
~
+60° (Foot length 1
℃
) or –22
~
+140
℉(
Foot length 1
℉)
Air pressure input range: 560
~
1066hPa (Foot length 1hPa) or 420
~
800mmHg(Foot length
1mmHg)or16.5
~
31.5inchHg (Foot length 0.1inchHg)
Atmospheric correction PPM input range: -999
~
+999 PPM (Foot length 1 PPM)
Prism constant input range: -99mm
~
+99mm (Foot length 1mm)
Reflector type
:
KTS-442UT series Total Station can be set visible laser distance measurement and unvisible