43
F1 turn on Laser direction
F2 turn off Laser direction
2. Laser Plummet will automatically turn on after entering the interface.
Press▲ or ▼: to adjust the brightness of laser plummet.
Brightness value 0 : the centering device shut down.
Brightness value 4 : the maximum value.
Laser plummet will turn off automatically after quite laser direction inferface.
Note: This fuction is only available on the instruments which equipped with Laser-plummet.
9.3 Distance and Angle Measurement
·
KTS-442UT supports angle measurement and distance measurement at the same time.
·
For recording measurement data, see “21.4. Recording Distance Measurement Data”.
·
Check the following once more before measuring a distance:
1
The KTS-442UT is set up correctly over the surveying point.
2
The battery is full charged.
3
The horizontal and vertical circle indexing is completed.
4
The parameters are set in conformity with measurement conditions.
5
The atmospheric correction factor has been set, the prism constant correction value has been
set, the distance measurement mode has been selected.
6
The center of the target is correctly sight, the light intensity of the returned signal is sufficiently
high.
PROCEDURE S/H/V selection and distance measurement
Operating Procedure
Operation
Display
⑴
In the first page of MEAS Mode, press SHV,
to select the desired distance mode.
Each time SHV is pressed, the distance
measurement mode changes.
S: slope distance
H: horizontal distance
V: height difference
SHV
Meas
.
PC -30
PPM 0
3
S m
ZA 89°59′54″
HAR 117°31′50″
P1
SDIST SHV HSET EDM
⑵
Press SDIST, when measurement starts,
EDM information (distance mode, prism
constant correction value, atmospheric correction
factor, distance measurement method) is
represented by a flashing display.
SDIST
Dist
.
Dist PC = -30
PPM = 0
Fine “r”
STOP