26
Operation procedure
Key
Display
(1) If instrument tilts over correction range, system
launch tilt correction function.
Tilt sensor
OFF X-ON XYON DIGIT
(
2)Leveling the instrument according to the related
chapter until the black point centered in the circle
X-ON: Only vertical angle be compensated
XYON: Both horizontal and vertical angle are
compensated
Press OFF , tilt correction will be off..
tilt sensor
OFF X-ON XYON DIGIT
(3)
DIGIT showing the tilt angle value respectively on
axis “X” and axis “Y”.
Once the“out of range ” shows on the screen, you
need to level the instrument manually until “out of
rang”disappears.
Tilt sensor 2- axis
X: out of range
Y: out of range
OFF X-ON XYON GRAPH
When the electronic bubble is centered, the system
goes back to previous screen.
Note
:
☆
For tilt correction, refer to “7.8 Explanations: Tilt auto correction”
☆
For contents of leveling instrument please refer to “2. Setup instrument”.
7.3 Display Illumination
·
In dark places, it is possible to illuminate the display so it is easy to see.
PROCEDURE Backlight Illumination ON/OFF
1. Press
to turn the illumination on.
2. Press
again to turn the illumination off.
7.4 Setting the Instrument Options
·
In setting Mode, make sure that the concerned parameters are set in accordance with measurement conditions.
·
To confirm or change the parameters options, see“19.1Changing Instrument Parameters”.
Table 1
: