153
PROCEDURE
Operating Procedure
Operation
Display
⑴
Press REC on the second page of the
“MEAS Mode Screen”.
REC
1. Stn data A:\JOB01
2. back sight data
3. angle data
4. dist data
5. Coord data
6. dist+ coord data
⑵
Select “3. Angle data” and press ENT (or
press numeric key 3), the “Angle Measurement
Data Recording Screen” is displayed.
“3. Angle
data”
+
ENT
REC/Angle
ZA 45°18′23″
HAR 87°23′09″
Pt.
:
POINT2000
ANGLE AUTO
⑶
Sight the target and press ANGLE, the
measurement results are displayed on line3 and 4
(lines indicated by *) of the “Measurement Data
Display Screen”. Values with no * are the angle
measurement values displayed in real time.
ANGLE
REC/Angle
*ZA 76°34′17″
*HAR 64°22′10″
Pt.
:
POINT2000
REC ANGLE AUTO
⑷
Press REC to record the angle measurement
data indicated by the “*”.
Set the following items: point number, code,
target height.
After each entry press ENT.
·
Maximum point number size: 14(alphanumeric)
·
Maximum code size: 16 (alphanumeric)
REC
*ZA 76°34′17″
*HAR 64°22′10″
Pt.
:
k2009
Code
:
KOLIDA
Tgt. h
:
1.67 m
SAVE CODE
⑸
Press SAVE to record data. Because the same
data can not be recorded a second time. REC is
not displayed after recording.
SAVE
REC/Angle
Pt.
:
POINT2000
ZA 45°18′23″
HAR 87°23′09″
ANGLE AUTO
⑹
ANGLE :measure the angle again.
ANGLE
REC/Angle
*ZA
*HAR
Pt.
:
POINT2001
REC ANGLE AUTO