48
PROCEDURE
Operating Procedure
Operation
Display
⑴
Press CRD. in the second page of the
“MEAS mode screen”, or press MENU in
the third page, the
Coordinate
Measurement Menu Screen
is displayed.
CRD.
or
MENU
Coord
1. Observation
2. Stn data
3. Back sight data
⑵
Select “2. Stn Data” and press ENT (or press
numeric key 2) to enter the station data.
“2. Stn
Data”
+
ENT
N0
:
1234.688
E0
:
1748.234 3
Z0
:
5121.579
Inst. h
:
0.000 m
Tgt. h
:
0.000 m
READ REC OK
(3) Set the following items: N0, E0
,
Z0
(instrument station coordinate), instrument height,
target height.
Each time you set an item, press ENT. Then
press F2 REC to record instrument station data,
then press F1 SAVE. For the method of setting
each item, see “17.4 Recording Instrument
Station Data”, then press F4 OK to record in
JOB. (you can also READ point from memory)
Enter the
station data
+
ENT
N0
:
1234.688
E0
:
1748.234 3
Z0
:
5121.579
Inst. h
:
1.600 m
Tgt. H
:
2.000 m
READ REC OK
⑷
Press OK, setting complete. Coordinate
measurement menu screen is displayed. You can
go to set 3.Backsight data
OK
Coordinate
1. Observation
2. Stn data
3. Back sight data
NOTE
:
Coordinates input range
-99999999.999 to +99999999.999 (m)
Instrument height input range
-9999.999 to + 9999.999 (m)
Target height input range
-9999.999 to +9999.999 (m)
☆
Stop entry in progress: ESC (return to the coordinate measurement menu screen)
☆
Reading in the coordinate data : Press READ
(
See “10.1.1 Reading in Registered Data”
)