TP-6252 2/08
16 Section 2 Operation
2.2 Marine Inspection
Kohler Co. recommends that all boat owners have their
vessels inspected at the start of each boating season by
the US Coast Guard, the local Coast Guard Auxiliary, or
local state agency.
Kohler Co. also recommends having the generator’s
exhaust system inspected at the start of each boating
season by an authorized Kohler
r
distributor/dealer.
Repair any problems identified before operating the
generator set.
Carbon monoxide.
Can
cause
severe
nausea,
fainting, or death.
The exhaust system must be
leakproof and routinely inspected.
WARNING
2.3 Angular Operation
See Figure 2-1 for angular operation limits.
Continuous
Intermittent—
3 minutes or less
25
_
30
_
Maximum value for all directions
Figure 2-1
Angular Operation
2.4 Operation in European Union
Member Countries
This generator set is specifically intended and approved
for operation below the deck in the engine compartment.
Operation above the deck and/or outdoors would
constitute a violation of European Union Directive
2000/14/EC noise emission standard.
2.5 Load Profile
Whenever operating the generator set, Kohler Co.
recommends maintaining the minimum load profile
indicated in Figure 2-1. Maintaining the load profile
prevents corrosion formation on internal engine
components when they’re exposed to the breakdown of
exhaust gases. Extended light loading may result in
engine “wet stacking”.
Minimum
Load Requirement
Ideal
Load Requirement
30% load
70% load or more
Figure 2-2
Load Profile
Wet Stacking
occurs when water vapor condenses in
the exhaust system.
At normal combustion
temperatures, water stays vaporized but at low
combustion temperatures, it condenses back to a liquid.
When running the generator set under normal loads
(30% load or more), diesel exhaust stays hot enough to
prevent water vapor from condensing. At low load
situations, wet stacking can occur.
The operator should perform all of the prestart checks.
Start the generator set according to the starting
procedure in the controller section of this manual. While
the generator set is operating, listen for a
smooth-running engine and visually inspect the
generator set for fluid or exhaust leaks.
Содержание 4.5EFOD
Страница 1: ...Marine Generator Sets Models 6EOD 4 5EFOD 8 32EOZD 6 5 27EFOZD TP 6252 2 08c Operation ...
Страница 8: ...TP 6252 2 08 8 Safety Precautions and Instructions Notes ...
Страница 48: ...TP 6252 2 08 48 Section 5 Wiring Diagrams GM42202 E Figure 5 2 Wiring Diagram for Model 6EOD 4 5EFOD ...
Страница 49: ...TP 6252 2 08 49 Section 5 Wiring Diagrams ADV7095A D Figure 5 3 Schematic for Model 6EOD 4 5EFOD Sheet 1 of 2 ...
Страница 50: ...TP 6252 2 08 50 Section 5 Wiring Diagrams ADV7095B D Figure 5 4 Schematic for Model 6EOD 4 5EFOD Sheet 2 of 2 ...
Страница 51: ...TP 6252 2 08 51 Section 5 Wiring Diagrams GM50490 B Figure 5 5 Wiring Diagram for Model 9EOZD 7EFOZD ...
Страница 58: ...TP 6252 2 08 58 ...
Страница 59: ...TP 6252 2 08 59 ...