TP-6252 2/08
39
Section 3 Scheduled Maintenance
Waterline
4
5
6
17
7
8
9
10
11
12
13
14
15
19
18
3
2
1
TP-5586-3
1. Silencer vertical lift 1.2 m (4 ft.) max.
2. Exhaust mixer elbow distance above waterline. If less than
23 cm (9 in.), a siphon break is required.
3. Siphon break distance above waterline 30.5 cm (1 ft.) min.
4. Siphon break
5. Exhaust mixer elbow
6. Heat exchanger (locations vary by model)
7. Coolant recovery tank
8. Locate coolant recovery tank at the same height as the heat
exchanger
9. Seawater strainer
10. Seacock
11. Intake strainer
12. Engine-driven seawater pump
13. Exhaust hose pitch 1.3 cm per 30.5 cm (0.5 in. per ft.) min.
14. Water lock (optional)
15. Silencer distance from exhaust mixer elbow 3 m (10 ft.) max.
16. Maximum distance between silencer and exhaust outlet of
1.5 m (5 ft.)
17. Silencer (customer supplied)
18. Exhaust hose pitch 1.3 cm per 30.5 cm (0.5 in. per ft.) min.
19. Exhaust outlet distance above the waterline 10 cm (4 in.) min.
16
Figure 3-12
Siphon Break (Plastic “U” Type) Installation
Note:
Consult the installation manual for complete
explanation of dimensions and other installation
considerations.
Содержание 4.5EFOD
Страница 1: ...Marine Generator Sets Models 6EOD 4 5EFOD 8 32EOZD 6 5 27EFOZD TP 6252 2 08c Operation ...
Страница 8: ...TP 6252 2 08 8 Safety Precautions and Instructions Notes ...
Страница 48: ...TP 6252 2 08 48 Section 5 Wiring Diagrams GM42202 E Figure 5 2 Wiring Diagram for Model 6EOD 4 5EFOD ...
Страница 49: ...TP 6252 2 08 49 Section 5 Wiring Diagrams ADV7095A D Figure 5 3 Schematic for Model 6EOD 4 5EFOD Sheet 1 of 2 ...
Страница 50: ...TP 6252 2 08 50 Section 5 Wiring Diagrams ADV7095B D Figure 5 4 Schematic for Model 6EOD 4 5EFOD Sheet 2 of 2 ...
Страница 51: ...TP 6252 2 08 51 Section 5 Wiring Diagrams GM50490 B Figure 5 5 Wiring Diagram for Model 9EOZD 7EFOZD ...
Страница 58: ...TP 6252 2 08 58 ...
Страница 59: ...TP 6252 2 08 59 ...