KGP-920
Chapter 8
Setup Procedure
93121662-00
8-17
8.6 Menu 9: Interface
8.6.1 Selecting an output data format of DATA port .
Initial setup: IEC
You can select the format of output data.
(1) Press [
MENU
] key until Menu options 1 to 9 appears.
(2) Press [
9
] key to select “
9:INTERFACE
”.
(3) Press [
1
] key to select “
1:FORMAT
”.
(4) Press [ ] or [ ] key to move cursor onto the output data format to choose.
(5) Press [
ENT
] key.
8.6.2 Editing the IEC 61162-1 output data format of DATA port
initial setup: Sentence: GGA, GLL, GBS, VTG, ZDA
Cycle: 1 second
You can select the output sentence and set the output cycle (in seconds) of the IEC 61162-1 output
data format.
(1) Press [
MENU
] key until Menu options 1 to 9 appears.
(2) Press [
9
] key to select “
9:INTERFACE
”.
(3) Press [
2
] key to select “
2:IEC EDIT
”.
(4) Press [ ] [ ] [ ] [ ] key to move cursor onto the sentence to change its cycle.
(5) Enter an output cycle of selected sentence using numeric keys.
(6) Press [
ENT
] key.
DATA port
Sentence Output
meter Output cycle (sec)
NOTE:
Set the output cycle for the required sentence only and set the unused data to "00". The output
meter indicates the ratio of total data amount (of selected sentence) to the data transmission
capacity (about 10% per scale). Do not maximize at 100% or poor performance may result.
Cursor