5-2
A-61593 September 2007
PCE1011
Task “{0}” failed
because of invalid
output path:
IMAGE_CHANNEL
in
tray output
File names related to a tray cannot contain the system field:
IMAGE_CHANNEL
.
Solution
: Delete the system field
IMAGE_CHANNEL
in the name of the
path in the Run Definition.
PCE1012
Task “{0}” failed
because of invalid
output path: Malformed
Symbol: {1}
The Run Definition is invalid for Convert because of the wrong syntax.
Solution
: Validate the Run Definition with the Convert Editor.
PCE1013
Task “{0}” failed
because of invalid
output path: Undefined
Symbol {1}
The Run Definition is invalid for Convert because an unknown symbol
was used.
Solution
: Validate the Run Definition with the Convert Editor.
PCE2001
Task “{0}” contains
inconsistent Scan data:
DOC_IN_TRAY not
incremented by 1 after
sheet
Internal error in the Scan module and its output.
Solution
: Save the log files of this task of Convert and Scan and send
them to Kodak Service.
PCE2002
Task “{0}” contains
inconsistent Scan data:
UN not incremented by
1 after sheet {1}
Internal error in the Scan module and its output.
Solution
: Save the log files of this task of Convert and Scan and send
them to Kodak Service.
PCE2003
Task “{0}” contains
inconsistent Scan data:
Not enough sheets
Internal error.
Solution
: Export Scan data using the Convert diagnostics function and
send the file to Kodak Service for further analysis.
PCE3001
Task “{0}” references
undefined converter
class
The defined converter class does not exist. There may be a typo in the
Converter class
field of the Run Definition.
Solution
: Check and correct the spelling of the
Converter class
field.
PCE3002
Task “{0}” contains
malformed converter
class parameters
The syntax of the
Converter class
field in the Run Definition is
malformed.
Solution
: Check and correct the spelling of the
Converter class
field.
PCE4000
Task “{0}” failed
because of invalid xml
file: {1}
Internal error because of a corrupt .xml file from Scan.
Solution
: Analyze the log files. Save the Scan data for reproduction.
PCE6000
Task “{0}” failed
because of invalid
“extended” parameter:
{1}
An unexpected parameter was used in some Output definition.
Solution
: Correct the Run Definition regarding the “extended” fields of
the output definitions of Convert and refer to the manual for a valid
parameter.
PCN - Native Converter errors
PCN5000
Task “{0}” failed
because of error in
NativeConverter {1}
Informational
: No error; successful.
PCN5001
Task “{0}” failed
because of error in
NativeConverter {1} I/O
error
Error in file handling.
Solution
: Close all programs (i.e., Viewer, etc.).
PCN5002
Task “{0}” failed
because of error in
NativeConverter {1}:
file already exists
One output file already exists.
Solution
: Delete this file.