6-3
SERVICE INFORMATION
The compressor suction and process stubs
can not be interchanged.
Refrigerant charge must be applied to the
high side only.
NOTE:
The ice maker cycle must be
initiated electrically. Do not try to manually
start the cycle.
Service defrost bimetals open at 50
°
F.
The defrost timer may contain a capacitor
in series with the motor. Do not test for
continuity when checking for a failed timer
motor. Instead, energize the timer, and
listen for gear movement.
The part number can be found on the
component.
IMPORTANT:
Refrigerant must be handled
by a licensed, EPA-certified refrigerant
technician in accordance with established
procedures. Remove the refrigerant from
the existing system per the instructions
provided with the recovery system being
used.
•
•
•
•
•
•
•
SERVICEABLE ELECTRICAL PARTS MATRIX COMPONENTS
PERFORMANCE DATA
• (NORMAL OPERATING CONDITIONS)
AMB WATTS
SYSTEM PRESSURE
(PSIG)
HIGH SIDE LOW SIDE
70
°
140±20
95±20
–7 TO 3
90
°
150±20
135±20
–4 TO 3
110
°
170±20
185±20
–2 TO 4
NOTE:
Watt and pressure readings will vary,
and are influenced by the existing condition of
the appliance, such as an iced-up evaporator,
the condition of the condenser, the defrost
cycle, pull-down time, and customer use.
Normal operating conditions are viewed
when the air and temperature controls are
at mid-setting, the freezer section is at 0 to
5
°
F, and the refrigerator is cycling.
•
Содержание KBFC42FS
Страница 8: ...1 4 NOTES ...
Страница 10: ...2 2 NOTES ...
Страница 22: ...3 12 NOTES ...
Страница 54: ...4 32 NOTES ...
Страница 66: ...6 4 NOTES ...
Страница 67: ...7 1 WIRING DIAGRAMS NOTE IM Solenoid valve and evap cover grounded through mounting ...
Страница 68: ...7 2 UNIT COMPARTMENT To Freezer Section To Refrigerator Section ...
Страница 69: ...7 3 REFRIGERATOR SECTION ...
Страница 70: ...7 4 FREEZER SECTION ...
Страница 71: ...7 5 REFRIGERANT ...
Страница 72: ...7 6 NOTES ...
Страница 76: ......