5-1
COMPONENT TESTING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
Refer to page 4-5 for the procedure for ac-
cessing the thermistor.
1. Unplug refrigerator or disconnect power.
2. Disconnect the thermistor connector from
the wiring harness.
3. Set the ohmmeter to the R x 10 scale.
4. Touch the ohmmeter test leads to the
connector pins. The meter should indi-
cate as shown in the chart.
NOTE:
If the resistance of the thermistor is
normal, perform the following voltage test.
5. Set the voltmeter to read a maximum
voltage of 10 volts DC.
6. Connect power to the refrigerator and al-
low it to enter the “cooling” mode.
THERMISTOR
Before testing any of the components, per-
form the following checks:
Control failure can be the result of corro-
sion on connectors. Therefore, disconnect-
ing and reconnecting wires will be neces-
sary throughout test procedures.
All tests/checks should be made with a
VOM or DVM having a sensitivity of 20,000
ohms-per-volt DC, or greater.
•
•
Check all connections before replacing
components, looking for broken or loose
wires, failed terminals, or wires not pressed
into connectors far enough.
Resistance checks must be made with pow-
er cord unplugged from outlet, and with wir-
ing harness or connectors disconnected.
Unless stated otherwise, make all resis-
tance checks by disconnecting the compo-
nent connector at the Central Control Unit
(CCU).
•
•
•
TEMP
RESISTANCE
TEMP
RESISTANCE
(
°
F)
Ω
(APPROX.)
(
°
F)
Ω
(APPROX.)
–5
25900-27500
45
5930-6300
0
22100-23500
50
5190-5510
5
18900-20000
55
4550-4830
10
16200-17200
60
4000-4240
15
13900-14800
65
3520-3730
20
12000-12800
70
3100-3300
25
10400-11000
75
2740-2910
30
8990-9550
80
2430-2580
32
8750
85
2160-2290
35
7800-8290
90
1920-2030
40
6800-7220
7. With the thermistor disconnected and the
refrigerator in the cooling mode, touch
the voltmeter test leads to the thermistor
main harness connector pins. The me-
ter should indicate approximately 5 volts
DC.
If the voltage is not present, check for
a thermistor output at the main control
board (see page 5-8).
Содержание KBFC42FS
Страница 8: ...1 4 NOTES ...
Страница 10: ...2 2 NOTES ...
Страница 22: ...3 12 NOTES ...
Страница 54: ...4 32 NOTES ...
Страница 66: ...6 4 NOTES ...
Страница 67: ...7 1 WIRING DIAGRAMS NOTE IM Solenoid valve and evap cover grounded through mounting ...
Страница 68: ...7 2 UNIT COMPARTMENT To Freezer Section To Refrigerator Section ...
Страница 69: ...7 3 REFRIGERATOR SECTION ...
Страница 70: ...7 4 FREEZER SECTION ...
Страница 71: ...7 5 REFRIGERANT ...
Страница 72: ...7 6 NOTES ...
Страница 76: ......