5-4
Refer to page 4-12 for the procedure for ac-
cessing the condenser fan motor.
1. Run the diagnostics tests (see page 6-2)
and check for the proper operation of the
condenser fan motor in step 04.
NOTE:
During the condenser fan motor op-
eration, 120 volts AC will be present at pins
1 and 4.
CONDENSER FAN MOTOR
1 2 3 4
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
EVAPORATOR FAN MOTOR
Refer to page 4-26 for the procedure for ac-
cessing the evaporator fan motor.
1. Run the diagnostics tests (see page 6-2)
and check for the proper operation of the
evaporator fan motor in step 03.
NOTE:
During the evaporator fan motor op-
eration, 5 to 17 volts DC will be present at the
yellow and white wires. A constant 12 volts at
the red and white wires will be present any-
time the fan motor is operating. The remaining
steps will allow you to check the resistance of
the evaporator fan motor.
2. Unplug refrigerator or disconnect power.
3. Disconnect the wire connector going to
the evaporator fan motor.
4. Set the ohmmeter to the R x 10K scale.
5. Touch the ohmmeter test leads to pins 1
(white wire) and 4 (red wire) of the evap-
orator fan motor connector. The meter
should indicate approximately 1400 to
1700
Ω
.
1 2
3 4
Содержание KBFC42FS
Страница 8: ...1 4 NOTES ...
Страница 10: ...2 2 NOTES ...
Страница 22: ...3 12 NOTES ...
Страница 54: ...4 32 NOTES ...
Страница 66: ...6 4 NOTES ...
Страница 67: ...7 1 WIRING DIAGRAMS NOTE IM Solenoid valve and evap cover grounded through mounting ...
Страница 68: ...7 2 UNIT COMPARTMENT To Freezer Section To Refrigerator Section ...
Страница 69: ...7 3 REFRIGERATOR SECTION ...
Страница 70: ...7 4 FREEZER SECTION ...
Страница 71: ...7 5 REFRIGERANT ...
Страница 72: ...7 6 NOTES ...
Страница 76: ......