![Kirby Morgan SuperLite 17B Скачать руководство пользователя страница 95](http://html.mh-extra.com/html/kirby-morgan/superlite-17b/superlite-17b_operation-and-maintenance-manual_1971910095.webp)
SuperLite
®
17B
© ⅯⅯⅩⅡ Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 120613005
81
7.8.6 SuperFlow
®
Demand Regulator
Removal from Helmet
Tools Required:
Torque Wrench and 1 1/4 inch Socket
1/4 inch Flat Blade Attachment on Torque Screwdriver
Torque Wrench and 11/16 Open-end Attachment
Torque Wrench and 13/16 Open-end Attachment
Torque Wrench and 7/8 inch Open-end Attachment
7/8 inch Open-end Wrench
1) To remove the regulator from the helmet, the bent
tube should be disconnected first. The bent tube as
-
sembly should be loosened at the side block and dis
-
connected from the regulator. It may now be swiveled
out of the way or completely removed.
2) Remove the whiskers from the port retainer by re
-
moving the screws. Take care not to lose the spacers
or kidney plates.
3) Remove the nose block device per Chapter 8.
Remove the whiskers from the helmet.
4) Remove the oral nasal mask.
5) The regulator mount nut is removed along with the
sealing O-ring.
6) Cut the tie wrap that connects the regulator body
to the Quad-Valve™ cover.
7) Now the regulator assembly can be pulled out of
the helmet.
8) The center section of the exhaust whisker wing,
named the exhaust main body has a tie wrap holding
it in place. Remove the tie wrap then stretch the body
off the regulator exhaust flange.
9) Older model double or single exhaust whiskers are
removed similarly.
Remove the mount nut from the regulator.
The regulator mount nut must be loosened with a wrench.