6.5.2 Emergency Valve Assembly
Without gas to the helmet, check “exercise” the
Emergency Gas Supply valve ensuring the valve
operates smoothly. Replacement/overhaul guidance
will be found in Chapter 7 of this manual.
6.5.3 Steady Flow/Defogger Valve
Without gas to the helmet, check, i.e., “exercise”
the Steadyflow/Defogger valve ensuring the valve
operates smoothly. Replacement/overhaul guidance
will be found in Chapter 7 of this manual.
6.5.4 Bias Device Adjustable Section of
Demand Regulator
Remove the regulator cover clamp, cover and dia
-
phragm and inspect the interior of the regulator body
for corrosion and contamination. Carefully inspect
the diaphragm for cuts, tears and deterioration. If
any damage is present replace the diaphragm, per
Chapter 7 of this manual.
Attach an air source to the umbilical adapter and
set the supply pressure to between 135-150 p.s.i.g.
(9.3-11.4 bar). Adjust the regulator knob out, until
a slight free flow develops, then, adjust in until the
free flow just stops and check the lever play. It should
be between 1/16” – 1/8” (1.5 – 3.0 mm). Adjust if
necessary, per Chapter 7. Reinstall the diaphragm,
the cover and the clamp.
6.5.5 Neck Clamp and Yoke Assembly
Inspect the neck clamp and yoke assembly and test
for proper operation per Chapter 8 of this manual.
6.5.6 Latch Catch Mechanism
Inspect the latch catch mechanism and test for proper