8.4.2 Handle Replacement
1) Clean off all the old RTV (silicone sealant) remain-
ing on the handle and the helmet shell and screw hole.
2) Place a liberal amount of RTV Dow Corning
®
RTV
732 or equivalent Multi Purpose sealant on the rear
mount surface of the handle and in the mount screw
hole in the helmet shell.
3) Position the handle and run in the front screws only
until snug.
4) Hold the handle in place and thread the rear mount screw
(90) with its washer. Torque to 20 inch pounds.
5) Tighten the front mount screws to 12 inch pounds.
6) Wipe off any excess RTV from the helmet shell.
Use a torque screwdriver to tighten the front handle
screws to 12 inch pounds.
ness. They can also cause long term
damage to body tissue. Read and follow
all precautions listed on the silicone seal-
ant tube and Material Safety Data Sheet.
WARNING
Use silicone sealant
in a well ventilated
area. Do not breathe
the fumes from un-
cured silicone seal-
ant. These fumes are
dangerous and can
cause unconscious-