![Kirby Morgan SuperLite 17B Скачать руководство пользователя страница 88](http://html.mh-extra.com/html/kirby-morgan/superlite-17b/superlite-17b_operation-and-maintenance-manual_1971910088.webp)
SuperLite
®
17B
74
© ⅯⅯⅩⅡ Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 120613005
Loosening the jam nut.
Always start removal at the side block end.
3) Pressurize EGS Valve to a minimum of 135 p.s.i.g.
(9.3 bar) using the EGS cylinder as supply. Allow sys
-
tem pressure to stabilize, and then shut the EGS supply
cylinder valve. Note time and final stabilized system
pressure.
4) Perform the leak check for minimum of five min
-
utes, using the mild soapy solution, per Chapter 6.
Ensure there is no gas flowing or pressure drop in the
system. There should be no visible signs of external
leakage if the valve is operating properly.
7.6 Bent Tube Assembly
7.6.1 General
The bent tube assembly provides breathing gas flow
from the side block assembly to the regulator assem
-
bly. Both ends of the bent tube assembly disconnect
for complete removal. The O-ring and the Teflon
®
O-ring should be replaced during normal overhauls or
any time these components are deemed unserviceable.
These components do not require replacement during
field repairs providing a careful visual inspection does
not reveal wear or damage. All soft goods should be
carefully cleaned in accordance with Chapter 6 prior
to inspection for reuse.
7.6.2 Removal of the Bent Tube Assembly
Tools Required:
11/16 inch Open-end Attachment on Torque Wrench
7/8 inch Open-end Attachment on Torque Wrench
7/8 inch Open-end Wrench
1) Always start removal of the bent tube at the side
block end. The free swiveling mount nut on this end
of the bent tube can be unthreaded completely and
can slide down the tube.
2) The inlet nipple has a jam nut that locks the mount
nut in place. With one wrench, hold the bent tube
mount nut. With another wrench, turn DOWN the jam
nut, backing it away from the mount nut. The mount
nut can then be rotated until free of the regulator inlet
nipple threads. It can be pushed up the bent tube.
3) With the two mount nuts free; the bent tube as
-
sembly can be pulled straight out of the regulator inlet
nipple. The bent tube assembly can be rotated back
and forth to aid removal.