![Kirby Morgan SuperLite 17B Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/kirby-morgan/superlite-17b/superlite-17b_operation-and-maintenance-manual_1971910033.webp)
SuperLite
®
17B
© ⅯⅯⅩⅡ Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 120613005
19
Handle
O-ring
Port retainer
Port
Helmet shell
Wing
Kidney plate
maximum of 1/4” at a time; trimming too much will
result in a loose fit.
NOTE: If you must trim the neck dam, be care-
ful not to trim off too much material. The neck
dam must fit snugly. While it may be a slight
bit uncomfortable out of the water, and may
feel snug, once in the water the neck dam will
loosen slightly.
WARNING
Pulling the neck dam over the diver’s head
can be difficult. Stretching (expanding) the
seal and placing it part way over the head
can help reduce the force needed to install
the seal. Proper training is necessary to in
-
stall the neck seal over the diver’s head and
onto their neck. Although the possibility is
very remote, injury may result if this proce
-
dure is not done properly. If a diver does not
know how to don the neck dam, they must
seek proper instruction before proceeding.
2.8.6 Reducing Carbon Dioxide
It is important to minimize the volume of air/gas
space that the diver is breathing through. Carbon
dioxide (CO2) can build up if proper flushing does
not occur. A silicone oral nasal mask is located inside
the helmet that fits over the diver’s nose and mouth.
The face port is held in position by the port
retainer.