![Kirby Morgan SuperLite 17B Скачать руководство пользователя страница 150](http://html.mh-extra.com/html/kirby-morgan/superlite-17b/superlite-17b_operation-and-maintenance-manual_1971910150.webp)
SuperLite
®
17B
136
© ⅯⅯⅩⅡ Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 120613005
4) Check the O-ring on the packing gland. Replace or
lubricate as necessary.
5) Install the W.P Connector assembly in the helmet shell.
6) Tighten the nut on the packing gland until snug.
7) Connect the wire lugs on the connector to the commu-
nications posts or terminal block as preferred.
8) Test the communications to ensure they are working.
The binding posts are sealed in place with silicone
sealant.
Make sure the holes in the binding posts are properly
aligned so that you will be able to thread the com-
munications wire through them easily when you are
ready to dive.
ness. They can also cause long term
damage to body tissue. Read and follow
all precautions listed on the silicone seal-
ant tube and Material Safety Data Sheet.
WARNING
Use silicone sealant
in a well ventilated
area. Do not breathe
the fumes from un-
cured silicone seal-
ant. These fumes are
dangerous and can
cause unconscious-
Removal of the waterproof connector.
3) Separate the connector/packing gland assembly from
the helmet shell.
4) Place the packing gland in a vice and unscrew the
packing nut.
5) Pull the connector through the gland.
NOTE: It will be much easier to do this if the lugs are
cut off the end of the connector first. Save the front and
back ferrules and the packing nut.
8.9.5.2 Connector Replacement
1) Lubricate the new connector with silicone lubricant (or
recommended equivalent).
2) Slide the packing nut and ferrules onto the new con-
nector.
3) Feed the connector through the packing gland.