9.3 Low Pressure Inflator Hose
Installation on the B Sideblock
The low-pressure inflator system is intended for use with
dry suits. For certain pieces of equipment it may be neces-
sary to use a longer inflator hose than is originally supplied
by the manufacturer of the low-pressure system. Regardless
all inflator hoses should have a limiting orifice that does
not allow a flow of more than 100 l.p.m.
Tools Required:
5/32 ” Allen Wrench Attachment on Torque Wrench
1) Remove the plug from the side block. Save this plug.
2) Check the O-ring on the low-pressure whip to be sure
it is present and in good condition.
3) Carefully screw the low-pressure whip into the side
block.
4) Tighten fitting to the specifications provided by the dry
suit manufacturer. Do not overtighten.
5) Pressurize helmet and test connection for leaks.
When using the low-pressure port on
the side block for attachment of a low-
pressure hose, a hose with built in flow
restriction or the KMDSI Flow Restric-
tor Adapter, P/N 555-210 must be used.
Without a restrictor, a hose failure could
deplete the Emergency Gas Supply very
rapidly leading to suffocation. This could
result in serious personal injury or death.
WARNING
To install the inflator hose, you will need to remove
the low pressure plug from the sideblock.
Install the low pressure hose in the block and test it
for leaks following installation. Be sure to save the
low pressure plug.