![Kirby Morgan SuperLite 17B Скачать руководство пользователя страница 181](http://html.mh-extra.com/html/kirby-morgan/superlite-17b/superlite-17b_operation-and-maintenance-manual_1971910181.webp)
SuperLite
®
17B
© ⅯⅯⅩⅡ Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 120613005
167
Appendix 3 Table 3 SuperFlow
®
350 Regulator High Pressure Regulated
Source
Depth
Regulator Setting
Surface Gauge in P.S.I.G.
Regulator Setting
Surface Gauge in BAR
FSW
MSW
Minimum
P.S.I.G.
Maximum
P.S.I.G.
Minimum
Bar
Maximum
Bar
0-60
0-18
150
225
10.3
15.5
61-100
19-30
200
250
13.8
17.2
101-132
31-40
250
275
17.2
18.9
133-165
41-50
250
300
17.2
19.6
*166-220
51-67
300
325
20.6
22.4
*May not be capable of performing at 75 RMV deeper than 165 FSW.
Performance is based on a minimum of 75 RMV to 165 FSW (50 MSW) and 62.5 RMV to 220
FSW (67 MSW) using a 3/8" (9.5 mm) umbilical 600 foot (183 meters) long, made up of two 300
foot (91 meter) sections.
Appendix 4 Standard Kirby Morgan Surface Supply Pressure
Formula - Old Method
Old Pressure Table Calculation:
The old method of determining supply pressure was to multiply the dive depth by .445 PSI and then add the
over-bottom pressure called out in the depth ranges for the depth from the KMDSI operations manual. The old
method was based on a minimum RMV of 62.5. This method can still be used. The old method used the formula
and called out over bottom pressures for depth as follows [(FSW x .445) + PSIG for depth] from the table below.
Depth in Feet and Meters
Over Bottom Pressure
0-60 FSW
(0-18 MSW)
90 PSIG (6.2 Bar)
61-100
(18-30) 115
(7.9)
101-132
(30-40)
135 (9.3)
133-165 (40-50)
165 (11.4)
166-220 (50-67)
225 (15.5)
For more information on determining supply pressure related information check the Dive Lab web site at www.
divelab.com.